Click for HOME Click for CONTENTS Click for INDEX Click for SEARCH Click for ORDER FORM Click for INFO blue95.gif (868 bytes)

line.gif (880 bytes)

   HYDRAULIC ELEVATOR BELT DRIVE - DRY POWER UNITS

  

Hydraulic elevator Belt Drive - Dry Power Units built with the motor and belt driven pump below oil tank. Valve mounted on top, inside tank. Removable covers provide access to main and shut off valves, belt tensioner, motor and pump. With tandem pump/motor up to 200HP/850GPM power unit can be customized to meet nearly any special project.

pu_belt.jpg (250976 bytes)

Typical dimensions:                                  
(48 or 60)” W x (34 or 43)” D x (60 to 77)” H


Hydraulic elevator belt drive - dry power units PDF flyer
Hydraulic elevator belt drive - dry power units PDF flyer Hydraulic elevator belt drive - dry power units PDF flyer.


Hydraulic elevator belt drive - dry power units worksheet/quote
Hydraulic elevator belt drive - dry power units worksheet/quote Hydraulic elevator belt drive - dry power units worksheet/quote.

Adobe Reader recommended.



Power Unit Standard Components


Motors
   • 208 VAC, 230 VAC, 460 VAC, 3 Phase 60 Hz
   • Single 15-100 HP
   • Tandem pump/motor up to 200 HP
   • 80 Starts/Hr. motors
Pumps
   • IMO pump
   • Single 43-425 GPM
   • Tandem pump/motor up to 850 GPM
   • Transferable oil up to 250 Gal.
Valves
   • EECO valve
   • Mounted in the tank, easy stand-up adjusting
   • Shut off ball valve in the tank
   • Stand-up adjusting
Tank
   • 12 Ga. formed tank and body
   •  Effective easy belt adjustment
   • Noise reducing muffler
   • Isolated pump/motor bedplate
   • Oil level sight gauge


Power Unit Customization


Motors
   • 120 Starts/Hr. motors

Pumps
   • Oil return pump

Valves
   • Maxton valve
   • Down speed regulated valve

Tank
   • Custom size tanks
   • Oil low pressure switch
   • Oil low switch
   • Oil heater in tank
   • Oil cooler external


Note:
Additional options are available.
Contact us if requested option is not listed above.

Electric Motor Data
MOTOR MOTOR CURRENT AMPS
HP Volt Full Load Starting Wye-Delta Locked Rotor X-Line
20 208 62 112 340
20 230/460 54/27 98/49 296/148
25 208 73 139 420
25 230/460 62/31 120/60 366/183
30 208 87 165 500
30 230/460 74/37 142/71 430/215
40 208 112 221 670
40 230/460 98/49 192/96 580/290
50 208 138 281 850
50 230/460 119/60 244/122 740/370
60 208 162 330 1000
60 230/460 143/72 304/152 920/460
75 208 210 436 1320
75 230/460 180/90 370/185 1120/560
100 230/460 228/114 524/262 1590/795
Note:
Locked Rotor AMPS are given for X-Line starting.
Starting AMPS are 1/3 Locked Rotor AMPS when starting Wye-Delta.

 