ELEVATOR SOLID STATE MOTOR STARTERS |
|
SIEMENS CLASS 72 SOFT STARTER
Alternative to electromechanical Wye-Delta and across the line motor starters.
Easy to install, simple wiring, no contacts to replace
No contacts to replace
LCD display for parameter settings and fault messages
Motor up to speed output and overload protection
Shorter SCR detection
Phase loss protection
|
FOR
6 OR 12 LEAD MOTORS |
FOR
3 OR 9 LEAD MOTORS |
Model |
HP@
200V |
HP@
230V |
HP@
460V |
HP@
200V |
HP@
230V |
HP@
460V |
7246025 |
7.5 |
10 |
25 |
- |
5 |
10 |
7246030 |
10 |
15 |
30 |
5 |
7.5 |
15 |
7223020 |
15 |
20 |
40 |
7.5 |
10 |
20 |
7223025 |
20 |
25 |
50 |
7.5 |
10 |
25 |
7223030 |
25 |
30 |
60 |
10 |
15 |
30 |
7223040 |
40 |
50 |
100 |
20 |
25 |
50 |
7223050 |
50 |
60 |
125 |
25 |
30 |
60 |
72230100 |
75 |
100 |
- |
40 |
50 |
- |
REPLACEMENT LOGIC BOARD
Model 72GBD01
Replacement logic board for Siemens class 72 Soft Starter.
|
|
MAGNETIC MOTOR STARTERS |
|
With solid state overload, full voltage, non-reversing, opening type.
Model
ESP14ESG32A |
7,5 HP at 200 volts
10 HP at 230 volts
(Nema size 1-3/4) |
Model ESP14GSJ32A |
15 HP at 200 volts
20 HP at 430 volts
(Nema size 2-1/2) |
Model ESP14HSK32A |
30 HP at 230
volts
50 HP at 460 volts
(Nema size 3) |
Model ESP14JTM32A |
50 HP at 230
volts
100 HP at 460 volts
(Nema size 4) |
|
|
SIEMENS 3TF3200 SERIES AC CONTACTORS |
|
Fast, safe terminal access. Each terminal accepts 2 wires.
Inrush capacity of 8.4 times rated full load current.
Snap on Din Rail or panel mount.
Cadmium free contacts
1N.O./1N.C. auxiliary contacts
Snap on accessories available
- Up to 4 auxiliary contacts
- Electronic or pneumatic timer
- Mechanical interlock
Model 3TF3211OAK6 10HP, 460V
Model 3TF3311OAK6 15HP, 460V
Model 3TF3511OAK6 25HP, 460V
|
|
SIEMENS 3UA5 SERIES OVERLOADS |
|
Class 10 tripping characteristics
Phase loss and unbalanced load protection
Trip indicator
Manual/auto reset
Model 3UA5200-2B 12.5-20
AMP
Model 3UA5200-2C 16- 25
AMP
Model 3UA5500-2Q 25-36 AMP
Model 3UA5500-2R 32-40 AMP
Model 3UA5500-8M 36-45 AMP
|
|
FURNAS CLASS 40 FULL VOLTAGE, HEAVY DUTY, MAGNETIC CONTACTORS |
|
Rugged industrial design
Easy coil access
Straight through wiring
Gravity dropout
Dual voltage coils
Model 40FP32AA Starter, Size 2
Model 40GP32AA Starter, Size 2.5
Model 40HP32AA Starter, Size 3
Model 40IP32AA Starter, Size 3.5
|
|
SOLID STATE OVERLOADS |
|
Phase loss protection
2% repeat trip accuracy
Manual reset
FLA adjustment dial with wide adjustment range
Heaterless design
Model 48BSF3M10 Overload,
13-27A
Model 48BSH3M10 Overload,
22-45A
Model 48BSJ3M10 Overload,
30-60A
Model 48BSK3M10
Overload, 45-90A
Model 48BSL3M10 Overload,
57-115A
Model 48BSM3M10 Overload,
67-135A
|
|
MECHANICAL INTERLOCKS |
|
Model 49GGF22H Mechanical Interlock
Model 49HHP22H Mechanical
Interlock
|
|