Engineered for maximum air distribution, our
fans are totally enclosed, pre-lubricated, easy to install, quiet and dependable.
Available with 115VAC or 220VAC single or two speed motor and 5-blade fan. Durable cages
made from 16-gauge welded steel. Round cages - galvanized, square black powder
coated. |
|
|
|
SSF3,
SSFE,
TSF1, TSFE
|
SSF3C,
TSF1C
|
SSF3R,
TSFE1420
TSFE1421, TSFE1424
|
Square Fans, AC
|
Speed |
CFM* |
Voltage |
Cage Dimensions |
Cage Opening |
Model SSF3 |
Single speed |
380 |
115VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
Model SSF3C** |
Single speed |
380 |
115VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
Model SSFE |
Single speed |
325 |
220VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
Model TSF1 |
Two speed |
345-300 |
115VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
Model TSF1C** |
Two speed |
345-300 |
115VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
Model TSFE |
Two speed |
325-290 |
220VAC, 50-60 Hz |
12 x 12 x 4-1/4 H |
10 x 10 |
* Approximate CFM values. ** 7/16 Dia.
cage holes to comply with California code. Lip 1 wide with four (4) mounting holes,
11 center to center.
Round Fans, AC
|
Speed |
CFM* |
Voltage |
Cage Dimensions |
Cage Opening |
Model SSF3R |
Single speed |
380 |
115VAC, 50-60 Hz |
14 Dia. x 4-1/2 H |
12 Dia. |
Model TSFE1421 |
Two speed |
325 |
115VAC, 50-60 Hz |
12 Dia. x 4-1/2 H |
10 Dia. |
Model TSFE1424 |
Two speed |
325 |
115VAC, 50-60 Hz |
14 Dia. x 3-1/2 H |
12 Dia. |
Model TSFE1420 |
Two speed |
325 |
115VAC, 50-60 Hz |
14 Dia. x 4-1/2 H |
12 Dia. |
* Approximate CFM values. Lip
1 wide with four (4) mounting holes, 13 center to center, and 11 for
TSFE1421.
Replacement Parts
Model 21FN001 |
Single speed AC fan motor |
Model 21FN002 |
Two speed AC fan motor |
Model A01FN001 |
Two speed suction blade |
Model A01FN002 |
Single speed suction blade |
Model A01FN003 |
Single/Two speed push blade |
|
|
STAND-BY
EMERGENCY VENTILATION FOR GLASS ELEVATORS
Ideal for use in glass elevators exposed to direct sunlight. Our fan with emergency power
source is designed to exceed the minimum ANSI A17.1- 2004 Section 2.14.2.3.3(b)
requirement of one hour. Durable cages made from 16-gauge welded steel, black powder
coated.
NOTE: Not intended as primary ventilation. |
|
|
|
SSF4DC
|
SSF4C
|
PP/SSF4DC
PP/SSF4DC-1 |
Square DC Fan With Power Supply
Square fan with 12VDC motor and
120VAC/12VDC power supply
Single speed, 300 CFM free air
Cage dimensions 12 x 12 x 4-1/4 H, cage opening 10 x
10
Lip 1 wide with four (4) mounting holes, 11 center to center
Bulb type thermostat operates the fan when elevator temperature reaches 80° and shuts off
when temperature decreases
to 75°, allowing greater time frame for emergency operation.
Model SSF4DC
Replacement DC Fan
Square fan with 12VDC motor, no power
supply included
300 CFM free air
Cage dimensions 12 x 12 x 4-1/4 H, cage opening 10 x
10
Lip 1 wide with four (4) mounting holes, 11
center to center
Model SSF4C
Replacement Emergency Power Supply
Sealed lead acid batteries for uniform discharge performance
Solid state charging system constantly maintains battery charge
Charging system 12" x 12" x 6" can be mounted horizontally or
vertically
Four hour power supply
Test switch, iIndicator lights (charging)
In the event of a power failure, the power supply will restore the charge at the rate of
eight hours for every four hours of discharge.
Model PP/SSF4DC 120VAC/12VDC
Model PP/SSF4DC-1 220VAC/12VDC
|
|
|
|
|